Combination product development and engineering support

Engineering analysis and development builds for the drug-device system: stack-ups from your drawings, specifications backed by data, margins found by testing, and representative filled and assembled units.

Answers before parts are tested

Some of the most useful answers in a program come from a set of drawings and a data set, long before the first device is tested.

A barrel, a plunger stopper and a plunger rod can each be in tolerance and still not work together. A stack-up across the drawings of every supplier combination shows where fit and function can fail, while the choice of supplier is still open. The same thinking applies to specifications: a limit set from registration and development data, and confirmed with validated testing, holds up better than one copied from a supplier datasheet.

Analysis only goes so far, so Kiln™ also finds margins by testing and builds the units the testing needs. Burst and stress testing shows how much load a syringe design can take. Engineering fill and device assembly produce representative samples, built to your specifications, so your test results reflect the product you will actually make. Methods we develop can then be transferred to your own lab, with fixtures and training.

123
  1. 1Barrel: dimensions and tolerances from each supplier's drawing
  2. 2Plunger stopper: dimensions and tolerances from each candidate
  3. 3Plunger rod: dimensions and tolerances of the rod that drives the stopper
Worst-case and statistical stack-ups combine the tolerances of each drawing, across every supplier combination under consideration.

What we do

Discrete pieces of work or support across a full program. Scope, sample requirements and deliverables are set per program.

Engineering analysis

Drawings and data, analyzed before you commit.

Tolerance stack-up analysis

Worst-case and statistical stack-ups of barrel, plunger stopper and plunger rod drawings across every supplier combination you are considering, so fit and function problems surface on paper instead of on the line.

  • Multi-supplier matrices
  • Drawing-based

Specification development and reliability

We analyze your registration and development data to recommend defensible performance specifications, confirm them with validated testing, and demonstrate reliability at the confidence level your risk file requires.

  • Process capability
  • Reliability statistics
  • Data review

Burst and stress testing

Burst resistance and destructive mechanical testing across syringe designs, to find margins and compare suppliers under the loads your device will actually apply.

  • Burst resistance
  • Supplier comparison

Methods your team can run

Methods developed and validated here, then set up in your lab.

Method transfer, fixtures and training

We develop and validate a method, machine a matched set of fixtures for your lab, and train your analysts on site, so your team gets the same results we do.

  • Custom fixturing
  • On-site training

Device disassembly methods

Methods that free the primary container from an autoinjector or safety device for integrity testing, confirmed not to disturb the seals.

  • Device disassembly
  • Seal integrity

Development builds

Representative samples, built to your specifications, for testing and development only.

Engineering fill

Small-scale filling of prefilled syringes and cartridges with peristaltic dispense and vacuum or mechanical stoppering, at nominal and at process extremes, with in-process fill weight and stopper height checks.

  • Process extremes
  • Vacuum stoppering

Device assembly process development

Semi-automated assembly of prefilled syringes into safety devices and autoinjectors, with force and torque monitored on every unit. Fixtures are designed to mirror your commercial line, and assembly limits are set from data rather than guesswork.

  • 100% in-process monitoring
  • Go / no-go fixtures
  • DV sample builds

Surrogate solutions

Placebo and surrogate solutions made to match your formulation's key properties, so filling, assembly and device testing can go ahead while drug product is reserved for the studies that need it.

  • Placebo
  • Formulation matching

Development decisions

Advice for the choices that are hardest to undo later.

Container and device selection

Guidance on choosing the primary container and delivery device that fit your formulation, your patients and your supply plan: glass or polymer, prefilled syringe or cartridge, platform device or custom, with the risks of each choice flagged before you commit.

  • Platform vs. custom
  • Risk assessment

Supplier survey and selection

We survey and compare offerings from primary container manufacturers, contract manufacturing organizations (CMOs), contract packaging organizations (CPOs) and device suppliers, side by side.

  • Supplier survey
  • CMOs and CPOs

How we work

Work is structured in phases with clear deliverables at each gate, so you always know what you have paid for and what comes next.

  1. Scope

    A working session on your system, your drawings, your data and your timeline. You get a phased proposal with sample requirements and deliverables spelled out.

  2. Analyze

    Stack-ups, data review and process capability come first, so testing and builds focus on the questions the analysis leaves open.

  3. Develop and validate

    Methods and fixtures are developed on your components, using placebo or surrogate wherever possible, and validated to a protocol.

  4. Build and test

    Engineering fills, assembly builds, burst and stress testing and specification confirmation run against the agreed protocols, with a report at each milestone.

  5. Transfer

    Validated methods stay available for later work, or transfer to your lab with a matched set of fixtures and on-site training.

Deliverables

Deliverables are defined in the proposal before work starts. A typical engagement includes some or all of the following.

Stack-up analysisWorst-case and statistical results for each supplier combination considered
Specification recommendationProposed specifications with the data analysis, process capability and reliability results behind them
Validated methods and fixturesProtocol, report and final test method, with fixtures and training where the method transfers
Development buildsFilled and assembled units with their in-process fill, stopper, force and torque records

Related services

Filling and surrogate solutionsSmall-scale filling at nominal and process extremes, with matched surrogates
Device assembly and packagingDevelopment builds with force and torque monitored on every unit
Supplier survey and selectionSide-by-side comparison of container makers, CMOs, CPOs and device suppliers
Functional testingForces, dose accuracy, injection time and depth, through aging and transit
Root cause investigationsCorrelating component variation to device performance when results drift
Devices we supportPrefilled syringes, cartridges, autoinjectors, pens, wearables and more

Questions we hear often

If yours isn't here, it's a good thing to bring to a consultation.

What can a tolerance stack-up show before parts exist?

Fit and function problems between the barrel, plunger stopper and plunger rod. We run worst-case and statistical stack-ups from the drawings across every supplier combination you are considering, so a problem shows up on paper instead of on the line.

How do you set a performance specification?

We analyze your registration and development data, including process capability, and recommend specifications you can defend. We then confirm them with validated testing and demonstrate reliability at the confidence level your risk file requires.

Can our own lab run the methods?

Yes. We develop and validate the method, machine a matched set of fixtures for your lab, and train your analysts on site. This can include device disassembly methods that free the primary container from an autoinjector or safety device for integrity testing.

Are development builds filled with drug product?

We fill placebo, water for injection or surrogate solutions matched to your formulation's key properties. Filled and assembled units are for testing and development only, not for human use.

Can you help us choose suppliers?

Yes. We survey and compare offerings from primary container manufacturers, contract manufacturing organizations (CMOs), contract packaging organizations (CPOs) and device suppliers, so the choice is based on a side-by-side view of what each can deliver for your program.

Working through a development decision?

Tell us about the system, the drawings or data you have, and where you are in the program. We'll set up a call to talk through scope, samples and timing.