Custom siliconization of glass and polymer syringes

Glass and polymer syringes re-siliconized to the silicone levels your study needs, verified by weight and by distribution scan, in lots from a few samples up to 5,000.

Why silicone level matters

Silicone oil is the lubricant that lets a plunger stopper move in a syringe barrel. How much there is, and how evenly it covers the barrel, affects most of what the system does.

Too little silicone, or a patchy layer, raises break-loose and glide force and can lengthen injection time in an autoinjector. Too much puts more droplets into solution, where they count as sub-visible particles. Silicone also moves over time, so a syringe that glides well at time zero can stick at twelve months.

A supplier's specification allows a range, and the syringes you receive for development usually sit somewhere inside it, not at the edges. Custom siliconization lets you test the edges deliberately, which is the only way to know your product and device have margin across what the supplier is allowed to ship.

LowNominalHighFlange endTip end
Illustration: silicone coverage mapped along the barrel at three target levels. The same scan is used for the as-received baseline and to verify each target.

What we do

We start from your as-received glass or polymer syringe barrels and return study-ready syringes at the silicone levels you specify.

Preparation

A known starting point, a known target and a measured result.

As-received mapping

Silicone coverage is mapped over the full inner surface of the as-received barrels. The scan is non-destructive, so the baseline is taken on the units that go on through the process.

  • Silicone distribution
  • Non-destructive

Strip and clean

Barrels are stripped of their existing silicone and cleaned, so that every unit starts from the same condition.

  • Stripping
  • Cleaning

Re-siliconization to target

Silicone is applied to the target levels you define, including the low and high ends of a supplier's specification. We spray silicone oil (Dow Corning 360, 1,000 to 12,500 cSt) with fixed or diving nozzles, or apply a silicone emulsion (Dow Corning 365 or 366) that is then baked on. Spray loads run from about 0.25 mg for low-silicone biologics syringes up to standard loads of 0.6 to 0.8 mg.

  • Sprayed-on
  • Baked-on emulsion
  • Low and high

Verification

Each target level is confirmed by silicone weight and by distribution scan before the containers leave the lab.

  • Silicone weight
  • Distribution scan

Study-ready containers

What happens after the silicone is on.

Packaging and sterilization

Re-siliconized barrels are packaged. Dry-heat (oven) sterilization is done in house by Kiln. If the syringes need to be autoclaved, or sterilized by ethylene oxide (EtO) or gamma irradiation, that work is done by a qualified partner.

  • Packaging
  • Dry-heat in house
  • Autoclave, EtO or gamma by partner

Filling and assembly

Syringes can be filled at Kiln with placebo, WFI or a surrogate solution, and assembled into your device. See filling and assembly and packaging.

  • Filling
  • Device assembly

Functional testing

Break-loose and glide force, and injection time in your device, measured on the low, nominal and high lots at time zero and across aging.

  • Break-loose and glide
  • Injection time

Particles

Sub-visible particle imaging on the same lots shows how silicone level changes what moves into solution.

  • Sub-visible particles

How we work

Work is structured in phases with clear deliverables at each gate, so you always know what you have paid for and what comes next.

  1. Scope

    We agree the container, the target silicone levels, the quantities and what testing follows.

  2. Map

    As-received barrels are scanned for silicone distribution to set the baseline.

  3. Prepare

    Barrels are stripped, cleaned and re-siliconized to each target level.

  4. Verify

    Each target level is confirmed by silicone weight and by distribution scan.

  5. Deliver

    Syringes are packaged and sterilized (dry heat in house, or autoclave, EtO or gamma through a qualified partner), then ship to you or move into filling and testing at Kiln.

Deliverables

Deliverables are defined in the proposal before work starts. A typical engagement includes the following.

Study-ready syringesAt each target silicone level, packaged and sterilized, in lots from a few samples up to 5,000
Baseline dataSilicone distribution of the as-received barrels
Verification dataSilicone weight and distribution scan for each target level
Test reportsIf functional or particle testing is part of the study

Related services

ISO 11040 testingComponent and finished-syringe testing for prefilled syringes and cartridges
Filling and surrogate solutionsSmall-scale filling at nominal and process extremes, with matched surrogates
ISO 11608 testingDesign verification for pens, autoinjectors and other needle-based injection systems
Device assembly and packagingDevelopment builds with force and torque monitored on every unit
Devices we supportPrefilled syringes, cartridges, autoinjectors, pens, wearables and more

Questions we hear often

If yours isn't here, it's a good thing to bring to a consultation.

Why test at the low and high ends of the silicone specification?

Because syringes at the edges of the specification can behave differently from the ones you received for development. Low silicone can raise glide force and lengthen injection time. High silicone can increase silicone droplets in solution. Testing at both ends shows whether your product and device have margin across the range a supplier is allowed to ship.

How do you verify the silicone level?

By silicone weight and by a distribution scan of the barrel. The scan is non-destructive, so the same unit can be followed through filling and aging.

Which formats and lot sizes do you handle?

Glass and polymer syringes, in lots from a few samples up to 5,000.

Do the syringes come back ready to fill?

Yes. We package the re-siliconized barrels and sterilize them. Dry-heat (oven) sterilization is done in house. Autoclave, ethylene oxide (EtO) or gamma sterilization is done by a qualified partner.

Can you run the testing on the custom syringes as well?

Yes. Filling, break-loose and glide force, device testing and sub-visible particle imaging can all be run at Kiln on the same lots.