ISO 11608 testing for pen injectors and autoinjectors
Design verification for pens, autoinjectors and other needle-based injection systems, run on your device with your primary container, using methods built and validated for that system.
What ISO 11608 covers
ISO 11608 is the series of standards for needle-based injection systems: devices that deliver a drug through a needle from a cartridge or a prefilled syringe.
Part 1 sets the general requirements and test methods for these systems, including dose accuracy. Part 3 covers the container and integrated fluid path, and Part 5 covers automated functions such as automatic needle insertion and injection. Which parts apply depends on how your device works, and that question is settled during scoping, before any protocol is written. We run all of the test annexes in the parts that apply.
Most autoinjector problems start at the interface between the device and the syringe inside it. A spring sized for one syringe and stopper can run slow with another, and a formulation that thickens in the cold can push injection time past its limit. Verification has to be run on the real combination, so that is how we run it.
- Remove capCap removal force, needle shield removal
- Press to activateActivation and override force
- InjectInjection time and depth, delivered dose, click-to-click time
- WithdrawNeedle shielding and lockout
What we test
Tests are chosen from your design inputs and the applicable parts of the standard. These are the ones we run most often.
Device function
How the device behaves when a user picks it up and injects.
Dose accuracy and delivered volume
Delivered dose and deliverable volume for single-dose autoinjectors, and dose accuracy across the dose settings of multi-dose pens. Formulation density is measured so that results can be reported as volume.
Activation and injection
Cap removal, activation and override force, injection time, injection depth and click-to-click time, measured on fixtures built for your device.
Needle shielding
Needle shielding and separation force for devices with integrated safety features, so that the safety function is verified alongside the injection.
Power pack simulation
The force profile of the device's drive spring is measured and then reproduced against candidate syringes and stoppers filled with a viscosity-matched solution. The result is a predicted injection time for each combination, before full devices are available.
Container and conditions
The primary container inside the device, and the device after storage and shipping.
Container and fluid path
Cartridge and plunger leakage, needle leakage, and septum fragmentation and resealability under repeated needle penetration, for pens and cartridge-based devices.
Aging, preconditioning and transit
Functional tests repeated after real-time and accelerated aging, environmental preconditioning and distribution simulation, so that verification covers the device as the patient receives it.
The syringe inside the device
Break-loose and glide force, critical dimensions and silicone distribution of the primary container, so that device results can be traced back to the container. See ISO 11040 testing.
Reference product benchmarking
For generic and biosimilar programs, the reference product's pen and cartridge are characterized side by side with yours: dimensions, dose accuracy, forces and leakage.
How we work
Work is structured in phases with clear deliverables at each gate, so you always know what you have paid for and what comes next.
-
Scope
We review the device, the container, your design inputs and regulatory plan, and agree which requirements apply. You get a phased proposal with sample quantities.
-
Develop
Fixtures are built for your device and each method is optimized, using placebo or a viscosity-matched surrogate where possible to save drug product.
-
Validate
Three test series by two operators on different days establish method precision. You receive the validation protocol, report and final test method.
-
Test
Verification runs against the validated methods at time zero and after aging, preconditioning and transit, as your plan requires.
-
Support
Methods stay available for stability pulls, investigations and lot release, or transfer to your own lab with fixtures and training.
Deliverables
Deliverables are defined in the proposal before work starts. A typical engagement includes the following.
Related services
Questions we hear often
If yours isn't here, it's a good thing to bring to a consultation.
Which parts of ISO 11608 apply to my device?
It depends on the device. Part 1 applies to needle-based injection systems in general. Part 3 covers the container and integrated fluid path, and Part 5 covers automated functions such as automatic needle insertion or injection. We review your device and design inputs during scoping and agree the applicable requirements with you before any protocol is written.
Can you predict injection time before we have devices?
Yes. We measure the force profile of the drive spring and reproduce it against your candidate syringes and stoppers, filled with a solution matched to your formulation's viscosity. That gives a predicted injection time for each combination while the device is still in development.
Can you test with placebo instead of drug product?
In most cases, yes. Method development is typically done with placebo or a surrogate solution matched to your formulation's key properties, such as viscosity and density. Drug product is reserved for the testing where it matters.
Do you test devices from any supplier?
Yes. We are platform-independent. Fixtures and methods are built around your specific device and primary container, whether it is a platform device or a custom design.
Can the methods be transferred to our lab?
Yes. We can develop and validate a method, build a matched set of fixtures for your equipment, and train your analysts on site.
Planning ISO 11608 testing?
Tell us about the device, the container and where you are in development. We'll set up a call to talk through scope, samples and timing.