Home / Devices we support
Drug-delivery devices we support
Development, testing and consulting for the device types used to deliver injectable drugs, from the primary container to the finished combination product.
One approach, many devices
Kiln works where the drug meets the device. Each device type below has its own failure modes and its own tests, but the approach is the same: methods written for your system, and data you can put in a design history file.
Prefilled syringes
Glass and polymer barrels, staked needle or luer, with rigid or soft needle shields. The syringe is the primary container for most autoinjectors and needle safety devices, so its behavior sets the limits for the device.
What we test
Critical dimensions, break-loose and glide force, needle shield removal, breakage forces, silicone distribution, sub-visible particles and container closure integrity, at time zero and through aging.
Cartridges
Crimp-sealed cartridges for pen injectors and on-body injectors. The crimp, the septum and the plunger each form a seal, and the septum has to survive repeated needle penetration.
What we test
Crimp and septum geometry, including crimp concentricity and septum bulge, plunger forces, leakage, inherent integrity of the crimp and plunger seals, and septum fragmentation and resealability.
Autoinjectors
Spring-driven, single-dose devices built around a prefilled syringe or cartridge. Performance depends on the match between the power pack, the formulation, the needle and the container.
What we test
Cap removal force, activation force, injection time and depth, delivered dose and needle shielding, with power pack simulation to predict injection time before devices exist. We also build development quantities and test the syringe inside the device for integrity.
Related services
ISO 11608 testing, Device assembly and packaging, Container closure integrity testing, Human factors.
Pen injectors
Multi-dose and single-dose pens with cartridges and pen needles. Dose accuracy across the dose range and the performance of the cartridge septum are the main questions.
What we test
Dose accuracy, injection force, cartridge and plunger leakage, and pen needle fragmentation and resealability. For generic and biosimilar programs, the reference product is benchmarked side by side with yours.
Related services
ISO 11608 testing, ISO 11040 testing, Supplier survey and selection.
Wearable pumps and on-body injectors
Devices worn on the skin that deliver a larger volume over minutes or longer. They add questions that hand-held devices don't have: whether the device stays on, and how it reaches the drug in its container.
What we test
Adhesive tack, peel and shear, septum penetration force at activation, flow rate, delivery time and delivered dose, and visible and sub-visible particles in the expelled dose.
Related services
ISO 11608 testing, Container closure integrity testing, Filling and surrogate solutions, Human factors.
Reconstitution devices
Devices that combine a drug with a diluent before injection. Kiln supports reconstitution device programs with development, testing and consulting.
What we test
Scope is set by the device design and your design inputs, and agreed during a consultation.
Related services
Supplier survey and selection, Human factors, Filling and surrogate solutions.
Needle safety devices
Passive and active safety systems added to a prefilled syringe to shield the needle after injection. Assembly loads and the fit with the syringe flange and needle shield matter as much as the safety function itself.
What we test
Activation and override force, needle shielding, and the force and torque of each assembly step. We assemble prefilled syringes into safety devices for development builds and design verification, and validate disassembly for integrity testing.
Related services
Device assembly and packaging, ISO 11040 testing, Container closure integrity testing.
Infusion systems
Syringe-driven and pump-driven delivery through infusion sets. Delivery rate and total delivered dose depend on the syringe, the set and the formulation together.
What we test
Flow rate, total delivery time and delivered dose across infusion sets and formulations, with the device held over a precision balance for the full delivery, and particle analysis of the expelled dose.
Related services
ISO 11040 testing, Filling and surrogate solutions, Supplier survey and selection.
Rescue products
Emergency-use products, where the device has to work the first time after long storage. Functional stability over shelf life is the central question.
What we test
For graduated and rescue syringes: dose and graduation accuracy, needle bond strength, stopper retention and leakage, carried through multi-year aging programs.
Related services
ISO 11040 testing, Container closure integrity testing, Human factors.
All services
Questions we hear often
If yours isn't here, it's a good thing to bring to a consultation.
Do you only work on these device types?
No. These are the device types we work on most. For novel delivery concepts we start by writing a method, because often one does not exist yet.
Do you work with devices from any supplier?
Yes. We are platform-independent and work with components and devices from any supplier. Fixtures and methods are built around your specific system.
Can you test the primary container and the device together?
Yes. Container testing and device testing can be run in the same program, with each component tracked through filling, assembly, aging and testing, so that device results can be traced back to the container.
Working on a device?
Tell us the device type, the container and where the program stands. We'll set up a call to talk it through.
Prefer email? Write to info@kiln-lab.com or call +1 (866) 350-8240.