KILN

Home / Filling and surrogate solutions

Filling and surrogate solution manufacturing

Small-scale filling of syringes and cartridges at nominal and at the process extremes, and placebo or surrogate solutions matched to your formulation, so that development testing runs on samples that look like your product.

Why the fill matters

Test results are only as representative as the samples. Fill volume, stopper position and headspace change how a syringe or cartridge behaves in almost every test that follows.

They change break-loose and glide force, injection time in a device, what a leak test can detect, and how far a stopper moves when a headspace bubble expands during air shipment. Development teams often need filled units before a commercial line exists, or need units deliberately made at the edges of the process window.

We fill syringes, cartridges and vials at small scale, and make surrogate solutions so that your drug product can be saved for the studies that need it. Filling is done in GMP conditions, but units are for testing and development only, not for human use. The process settings we arrive at are documented and handed over, so they can inform your commercial fill.

LowNominalHighStopperposition range

Each condition is set in an engineering run, then checked for fill weight and stopper height at the beginning, middle and end of the fill.

Illustration: units filled at the low and high extremes of fill volume and stopper position, alongside nominal.

What we do

Filled units are built to your specifications and can go straight into assembly and testing.

Filling

Engineering fill and finish for development work.

Syringe, cartridge and vial filling

Small-scale filling of prefilled syringes from 0.5 mL long to 5 mL, cartridges from 1 to 10 mL (including dual chamber cartridges) and vials from 2R to 20R, with placebo, WFI or a surrogate solution, using peristaltic dispense and vacuum or mechanical stoppering. Filling is done in GMP conditions, including a restricted access barrier system (RABS) with ISO 5 conditions. Batch sizes run from a couple of samples up to 40,000 units. Filled units are for testing and development only, not for human use.

  • Peristaltic dispense
  • Vacuum stoppering
  • Mechanical stoppering
  • RABS, ISO 5
  • GMP conditions
  • Not for human use

Process extremes

An engineering run sets the parameters for each condition. Units are then filled at nominal and at the low and high extremes of fill volume and stopper position, so later testing covers the range a commercial process will produce.

  • Fill volume
  • Stopper position

In-process checks

Fill weight and stopper height are checked at the beginning, middle and end of every run, and reported with each condition.

  • Fill weight
  • Stopper height

Documented settings

Fill and stoppering parameters for each condition are recorded and given to you, along with the protocol for the run.

  • Process parameters
  • Protocol

Surrogate solutions and samples

Liquids and filled units for testing when drug product is scarce.

Surrogate solution manufacturing

Placebo and surrogate solutions made with your excipients where possible and matched to your formulation's key properties, such as viscosity and density, with the match confirmed by measurement.

  • Surrogate solutions
  • Viscosity matching

Samples for device builds

Filled syringes and cartridges move directly into device assembly at Kiln for development builds. See assembly and packaging.

  • Development builds
  • Device assembly

Samples for testing

Filled units go on to functional testing, container closure integrity testing, aging and transit studies, with each unit traceable back to its fill condition.

  • Traceability
  • Aging and transit

How we work

Work is structured in phases with clear deliverables at each gate, so you always know what you have paid for and what comes next.

  1. Scope

    We agree the containers, the liquid, the fill volumes and stopper positions, the quantities and what the units will be used for.

  2. Prepare

    Surrogate solution is made and checked against the target properties, and the filling setup is adjusted for your container.

  3. Set up

    An engineering run dials in fill and stoppering parameters for each condition.

  4. Fill

    Units are filled and stoppered at each condition, with fill weight and stopper height checked at the beginning, middle and end.

  5. Deliver

    Units ship to you with the run data, or move into assembly and testing at Kiln.

Deliverables

Deliverables are defined in the proposal before work starts. A typical engagement includes the following.

Filled unitsAt the fill volumes and stopper positions you specify
Run dataIn-process fill weight and stopper height results for each condition
Process settingsThe fill and stoppering parameters used, documented
Surrogate solutionMade to the properties you define, with the measurements

Related services

Device assembly and packagingDevelopment builds with force and torque monitored on every unit
Custom siliconizationSyringes re-siliconized to target levels for studies across the silicone range
Container closure integrity testingLeak test methods developed and validated under USP <1207> and ASTM F2391
ISO 11040 testingComponent and finished-syringe testing for prefilled syringes and cartridges
Devices we supportPrefilled syringes, cartridges, autoinjectors, pens, wearables and more

Questions we hear often

If yours isn't here, it's a good thing to bring to a consultation.

What can you fill with?

We fill syringes (0.5 mL long to 5 mL), cartridges (1 to 10 mL, including dual chamber cartridges) and vials (2R to 20R) with placebo, WFI or a surrogate solution. Filling is done in GMP conditions. Filled units are for testing and development only, not for human use. Batch sizes run from a couple of samples up to 40,000 units.

What is a surrogate solution?

A solution made to match the key physical properties of your formulation, such as viscosity and density, without the active ingredient. It lets filling, assembly and device testing go ahead when drug product is scarce or expensive.

Why fill at process extremes?

Because a commercial process produces a range of fill volumes and stopper positions, not only the nominal. Filling at the low and high extremes shows how the syringe, the device and the integrity methods behave across that range.

Can filled units go straight into testing?

Yes. Units filled at Kiln can go directly into device assembly, functional testing, container closure integrity testing, aging and transit studies.

Need filled samples?

Tell us the container, the liquid and the quantities. We'll set up a call to talk through fill conditions and timing.

Prefer email? Write to info@kiln-lab.com or call +1 (866) 350-8240.